Cisco ASA: Qu'est-ce que le compteur «tx se bloque» sur l'interface d'exposition?

12

Considérez la sortie suivante de show interface:

Interface GigabitEthernet0/1 "inside", is up, line protocol is up
  Hardware is i82546GB rev03, BW 1000 Mbps, DLY 10 usec
    Full-Duplex(Full-duplex), 1000 Mbps(1000 Mbps)
    Input flow control is unsupported, output flow control is off
    MAC address 5057.aaaa.25d7, MTU 1500
    IP address 10.0.0.7, subnet mask 255.255.255.0
    2708954646 packets input, 1614638330819 bytes, 0 no buffer
    Received 786860 broadcasts, 0 runts, 0 giants
    7262 input errors, 7262 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
    0 pause input, 0 resume input
    0 L2 decode drops
    2622997029 packets output, 1295347863682 bytes, 6396 underruns
    0 pause output, 0 resume output
    0 output errors, 0 collisions, 90 interface resets
    0 late collisions, 0 deferred
    0 input reset drops, 7908 output reset drops, 31 tx hangs

La dernière ligne dit 31 tx hangs. Qu'est-ce que ça veut dire?

tunnelsup
la source
C'est une très bonne question, à partir d'aujourd'hui il n'y a rien dans les documents ASA que je puisse trouver.
Mike Pennington

Réponses:

5

Un blocage fait généralement référence à une transmission de trame Ethernet qui "prend trop de temps", entraînant une réinitialisation du contrôleur ou de l'interface. Ce qui "prend trop de temps" signifie cependant un peu mystérieux.

Santino
la source
Je ne sais pas si c'est la bonne réponse, mais c'est la meilleure réponse, donc je vous en rendrai hommage.
tunnelsup